Skydivers in a circle

BRL 5602 plastics piping systems of PE-RT intended for underfloor heating

The products according BRL 5602 are applicable for piping systems in underfloor heating systems at a design (working) overpressure of 4 or 6 bar according the temperature profile class 4 in table 1.

For the application in floorheating circulation systems in high buildings the design (working) overpressure should be 10 bar according the temperature profile in table 1

 Tabel 1 – Temperature profile during 50 years

  Temperature 
[ ºC]
Time Overall service coëfficiënt
Tcold 20 2,5 years 1,25
Tdesign 40+60 20 years+25 years 1,5
Tmax 70 2,5 years 1,3
T malfunction 100 100 hours 1,0
Remark: the mentioned temperature 
profile is in accordance with class 4 of ISO 10508.
     

Installers/plumbers, architects, contractors, municipalities, housing association