BRL 5603 Plastics piping systems of PE-X intended for underfloor heating
The products according BRL 5603 are applicable for piping systems in underfloor heating systems at a design (working) overpressure of 4, 6 or 10 bar according the temperature profile class 4 in table 1.
Receive a quote tailored to your needs
Tabel 1 – Temperature profile during 50 years
| Temperature [ ºC] |
Time | Overall service coëfficiënt | |
| Tcold | 20 | 2,5 years | 1,25 |
| Tdesign | 40+60 | 20 years+25 years | 1,5 |
| Tmax | 70 | 2,5 years | 1,3 |
| T malfunction | 100 | 100 hours | 1,0 |
| Remark: the mentioned temperature profile is in accordance with class 4 of ISO 10508. |
Installers/plumbers, architects, contractors, municipalities, housing association