Warehouse Racking Inspections by Kiwa KVVM
Receive a quote tailored to your needs
In many warehouses, the focus is on working quickly and efficiently, which can sometimes cause legal obligations and safety requirements to receive less attention. Damage to a warehouse rack, for example, can have serious consequences if it is not detected and addressed in time. Responsibility for warehouse safety is therefore often assigned to a specific employee. But how can that person be certain that the warehouse provides a safe workplace for staff?
A warehouse racking inspection by Kiwa KVVM helps you gain clear insight into the condition and safety status of your storage systems. We offer the following inspection services:
• Periodic warehouse racking inspections
• One-time warehouse racking inspections
• Post-renovation warehouse racking inspections
Kiwa KVVM inspects warehouse racking systems using its own inspection methodology, developed in accordance with applicable legislation and industry standards.
Periodic Warehouse Racking Inspections
During periodic warehouse racking inspections, our inspectors assess any damage, defects, and deviations from applicable standards. The inspection is carried out using Kiwa KVVM’s proprietary methodology. Following the inspection, you will receive a comprehensive report based on Dutch and European standards and regulations.
The inspection report is available immediately after completion of the inspection and includes a detailed explanation from our inspector. You will also receive a Kiwa KVVM Proof of Inspection. In addition, Kiwa KVVM offers the possibility of obtaining an Inspection Certificate. Once all identified non-conformities have been resolved and successfully reassessed, a Kiwa KVVM Inspection Certificate will be issued.
One-Time Warehouse Racking Inspection
We can perform a one-time inspection of your warehouse racking systems, for example when an independent second opinion is required. The inspection is carried out in the same manner as an annual inspection and includes a baseline assessment.
A one-time inspection is often used for temporary warehouses or storage facilities. It is also suitable for inspecting a specific section of a warehouse or mezzanine floor. Furthermore, a one-time inspection may be required as a supplement to a Risk Inventory and Evaluation (RI&E) report.
Warehouse Racking Inspection Following Renovation or Modification
Following renovation work or operational changes, the original design specifications of the racking system or warehouse layout may no longer be valid. This may affect load capacity information displayed on load signs, as well as the positioning of goods within the racking system. In addition, standards and best practices regarding anchoring requirements may have evolved over time. The year of installation of the racking system determines which standards are applied during the inspection.
To ensure a safe warehouse and working environment after renovation or modification, it is common practice to carry out an inspection to verify continued compliance with occupational health and safety requirements. Kiwa KVVM can also perform a new baseline assessment for your facility.
A warehouse racking inspection by Kiwa KVVM provides valuable insight into the condition of your storage systems and helps you determine any corrective actions that may be necessary. By doing so, you fulfil your duty of care as an employer and help ensure a safe working environment for your employees in accordance with occupational health and safety legislation.
Our inspectors are professionally trained, VCA certified, and hold industrial climbing certifications. Our service vehicles are equipped with calibrated measuring equipment to ensure accurate and reliable inspections.
Service Area
Kiwa KVVM carries out warehouse racking inspections throughout the Netherlands and in neighbouring European countries.
Applicable Standards for the Structural Design of Warehouse Racking Systems
The following standards apply to the structural design of warehouse racking systems:
- Pallet racking systems: EN 15512 and EN 16681 (for seismic areas)
- Mobile racking systems: EN 15095
- Shelving systems: FEM 10.2.6-1 and FEM 10.2.6-2 (multi-tier installations)
- Drive-in and drive-through racking systems: FEM 10.2.7
- Cantilever racking systems: FEM 10.2.9
- Applicable Standards for Dimensional Requirements, Operational Use and Project Specifications
The following standards and guidelines apply to dimensional requirements, project specifications and the safe use of storage equipment:
- EN 15620 – Steel static storage systems – Tolerances, deformations and clearances.
- EN 15629 – Steel static storage systems – Specification of storage equipment.
- EN 15635 – Steel static storage systems – Application and maintenance of storage equipment.
- NPR 5054 – Pallet racking systems operated by industrial trucks – Project specification related to the Declaration of Permitted Use.
- NPR 5055-1 – Warehouse racking systems – Occupational health and safety responsibilities and checklists for periodic inspections regarding correct use and maintenance. Part 1: Pallet racking systems.
- NEN 5051 – Warehouse racking systems – Design information to be provided by the purchaser and instructions for installation and use (withdrawn standard).
- NEN 5056 – Non-mobile steel storage systems – Adjustable pallet racking systems – Technical basis for design, including deviations from and additions to EN 15512:2009 (withdrawn standard).
- EN ISO 14122 applies to permanent means of access to machinery, including working platforms, walkways, stairs, ladders and guardrails.
Why Kiwa?
Kiwa Fire Safety & Security (Kiwa FSS) is a leading TIC company specializing in the Testing, Inspection and Certification of products, installations and organizations in the fields of fire safety, life safety and security. Our TIC services contribute to quality, safety, health, reliability and sustainability. In addition, we provide training services from a fully independent, objective and impartial position.
Kiwa KVVM is an independent inspection body specializing in the safety of warehouse racking systems, rack-supported mezzanine floors and free-standing mezzanine floors. We deliver our services in a professional, flexible, customer-focused and innovative manner.
Our services include carrying out inspections and providing training from a fully independent, objective and impartial position. All Kiwa KVVM inspectors are VCA certified and hold an industrial climbing certificate, enabling them to safely and effectively inspect warehouse storage systems at height.
This combination of expertise, independence and practical experience makes Kiwa KVVM a trusted partner for ensuring the safety and compliance of your warehouse environment.
Inspection of Stairs, Ladders & Mobile Scaffold Towers by Kiwa KVVM
Keep your access equipment safe and compliant with inspections by Kiwa KVVM. Expert inspections of stairs, ladders and mobile scaffold towers across the Netherlands and Europe.
Rack Damage Investigation by Kiwa KVVM
Rack damage or collapse can have serious consequences for safety, operations and business continuity. Kiwa KVVM provides independent rack damage investigations, helping you identify the root cause of failures, assess risks and implement effective corrective actions to restore a safe and compliant warehouse environment.
Inspection Emergency Lighting
During an Emergency Lighting Inspection, Kiwa assesses the basic assumptions for the emergency lighting as well as the design data to determine that emergency lighting meets the objective.
Inspection Fire alarm and Evacuation Alarm Systems
In case of fire, fire alarm and evacuation alarm systems are crucial for the safety of occupants in a building and minimising damage. Kiwa FSS is the expert for inspection and certification of fire alarm systems and evacuation alarm systems, see here for more information!
Internal Inspection of Sprinkler System Piping
An automatic sprinkler system must have a reliable pipe system for optimal operation. An internal Inspection of Sprinkler System Piping will give you an insight into the current condition of your sprinkler system.
Kiwa FSS Testing: test lab for sprinklers
Sprinkler systems have proven to be a reliable fire-protection system for many years. However, many of these systems are showing their age and it is not uncommon to find sprinkler systems that were installed 25 or more years ago. The sprinklers in these systems are dated and will need to be replaced over time as a preventative measure.
Quick scan Fire Safety in Buildings
Kiwa FSS’s quick scan Fire Safety in Buildings is an independent investigation to determine the current status of fire safety precautions.
NEN 3140 Inspection: Have Your Electrical Equipment Inspected by Kiwa KVVM
Ensure the safety and compliance of your electrical equipment with a professional NEN 3140 inspection by Kiwa KVVM. Our expert inspectors perform thorough assessments, helping you reduce risks, prevent failures and demonstrate compliance with Dutch health and safety requirements.